NIBE Heating is the largest manufacturer of ground source heat pumps in the Scandinavian countries and one of the largest in Europe. The company's goal is to be a leader in heat pump manufacturing and to produce top-class heat pumps at a very attractive price. NIBE ground source heat pumps have the highest COP values compared with leading manufacturers. This means that NIBE ground source heat pumps consume less electricity, leaving you with more money for other expenses.
Using a ground source heat pump, solar energy stored in the ground can be extracted and used for home heating. Heat under the ground surface begins to accumulate from the first spring days, when the ground starts to thaw, and especially abundantly in mid-summer, when midday sunlight warms the ground. By the time the leaves fall from the trees and begin to collect on the ground, enough energy has accumulated there to heat the home throughout the winter. Heat pumps capture, transfer and transform this naturally occurring heat to maintain a pleasant indoor temperature. Conversely, if it becomes too hot in summer, the same system can also be used for cooling rooms.
With the latest-generation NIBE ground source heat pumps, you can save up to 80% on heating costs. The reason is that the ground source heat pump uses the ground, the upper soil layer or a nearby lake as its main energy source, and all this energy is available free of charge. NIBE heat pumps make it easier, cheaper and more complete to use ground energy. The return on investment in a ground source heat pump is immediate, as heating bills will decrease significantly.
NIBE ground source heat pump FIGHTER 1126
This is the highest Swedish quality at the lowest price! A highly economical heat pump for heating private homes and small industrial facilities, with an additional boiler for domestic hot water preparation. High efficiency thanks to an efficient compressor and a perfectly dimensioned refrigerant circuit.
| Type, NIBE F1126 | 6 kW | 8 kW | 11 kW |
|---|---|---|---|
| Heating capacity (B0/W35 and B0/W50)* | 5,56/5,34 kW | 7,63/6,32 kW | 11,01/10,32 kW |
| COP at B0/W35 and B0/W50* | 4,55/3,25 | 4,71/3,36 | 4,55/3,36 |
| Height, mm (without adjustable feet 30-50 mm) |
1500 | 1500 | 1500 |
| Width, mm | 600 | 600 | 600 |
| Depth, mm | 620 | 620 | 620 |
| Net weight, kg | 160 | 170 | 175 |
| Operating voltage | 400 V (3-phase + neutral) | 400 V (3-phase + neutral) | 400 V (3-phase + neutral) |
| Refrigerant | R407C | R407C | R407C |
| Collector length, m | 250-350 | 325-2×250 | 2×230-2×300 |
| Borehole, m | 90-110 | 120-140 | 180-200 |
| Price, EUR incl. VAT | 4600 | 4840 | 5205 |
*In accordance with standard EN 255 at a collector temperature of 0° C / heating temperature of 35° C and at a collector temperature of 0° C / heating temperature of 50° C. The electrical power of the circulation pumps is not included.
NIBE ground source heat pump FIGHTER 1145
NIBE F1145 The latest-generation NIBE ground source heat pumps are not only more efficient than previous models, but also more user-friendly. A ground source heat pump for heating private homes, apartment buildings and small industrial buildings
It operates so quietly that you will not notice its presence!
| Type, NIBE F1145 | 6 kW | 8 kW |
|---|---|---|
| Heating capacity (B 0 / W 35) * | 6,3 kW | 8,3 kW |
| Heating capacity (B 0 / W 50) ** | 5,1 kW | 6,9 kW |
| COP (B 0 / W 35) * | 4,93 | 5,01 |
| COP (B 0 / W 50) ** | 3,46 | 3,54 |
| Height | 1500 mm | 1500 mm |
| Width | 600 mm | 600 mm |
| Depth | 620 mm | 620 mm |
| Net weight | 145 kg | 165 kg |
| Operating voltage | 400 V (3-phase + neutral) | 400 V (3-phase + neutral) |
| Refrigerant | R407C | R407C |
| Price, EUR incl. VAT | 5565 | 5810 |
*In accordance with standard EN 255 at a collector temperature of 0° C / heating temperature of 35° C. The electrical power of the circulation pumps is not included.
**In accordance with standard EN 255 at a collector temperature of 0° C / heating temperature of 50° C. The electrical power of the circulation pumps is not included.
| Type, NIBE F1145 | 10 kW | 12 kW |
|---|---|---|
| Heating capacity (B 0 / W 35) * | 10,0 kW | 11,8 kW |
| Heating capacity (B 0 / W 50) ** | 8,5 kW | 11,2 kW |
| COP (B 0 / W 35) * | 5,03 | 4,8 |
| COP (B 0 / W 50) ** | 3,39 | 3,4 |
| Height | 1500 mm | 1500 mm |
| Width | 600 mm | 600 mm |
| Depth | 620 mm | 620 mm |
| Net weight | 170 kg | 178 kg |
| Operating voltage | 400 V (3-phase + neutral) | 400 V (3-phase + neutral) |
| Refrigerant | R407C | R407C |
| Price, EUR incl. VAT | 5930 | 6170 |
*In accordance with standard EN 255 at a collector temperature of 0° C / heating temperature of 35° C. The electrical power of the circulation pumps is not included.
**In accordance with standard EN 255 at a collector temperature of 0° C / heating temperature of 50° C. The electrical power of the circulation pumps is not included.
| Type, NIBE F1145 | 15 kW | 17 kW |
|---|---|---|
| Heating capacity (B 0 / W 35) * | 15,8 kW | 17,2 kW |
| Heating capacity (B 0 / W 50) ** | 15,1 kW | 16,4 kW |
| COP (B 0 / W 35) * | 4,8 | 4,6 |
| COP (B 0 / W 50) ** | 3,4 | 3,4 |
| Height | 1500 mm | 1500 mm |
| Width | 600 mm | 600 mm |
| Depth | 620 mm | 620 mm |
| Net weight | 191 kg | 199 kg |
| Operating voltage | 400 V (3-phase + neutral) | 400 V (3-phase + neutral) |
| Refrigerant | R407C | R407C |
| Price, EUR incl. VAT | 6535 | 7140 |
*In accordance with standard EN 255 at a collector temperature of 0° C / heating temperature of 35° C. The electrical power of the circulation pumps is not included.
**In accordance with standard EN 255 at a collector temperature of 0° C / heating temperature of 50° C. The electrical power of the circulation pumps is not included.
NIBE ground source heat pump FIGHTER 1245
NIBE F1245 is a complete ground source heat pump for private homes with a built-in 180-litre domestic hot water storage tank. The latest-generation NIBE ground source heat pumps are not only more efficient than previous models, but also more user-friendly.
Install a NIBE heat pump and you can reduce energy consumption by up to 75%
The high efficiency of the heat pump means that you can obtain as much hot water as you and your family need, and the amount of hot water is quickly restored after use.
| Type, NIBE F1245 | 6 kW | 8 kW |
|---|---|---|
| Heating capacity (B 0 / W 35) * | 6,3 kW | 8,3 kW |
| Heating capacity (B 0 / W 50) ** | 5,1 kW | 6,9 kW |
| COP (B 0 / W 35) * | 4,93 | 5,01 |
| COP (B 0 / W 50) ** | 3,46 | 3,54 |
| Height | 1800 mm | 1800 mm |
| Required opening height for installation | 1950 mm | 1950 mm |
| Hot water tank volume | 180 litres | 180 litres |
| Width | 600 mm | 600 mm |
| Depth | 620 mm | 620 mm |
| Net weight | 310 kg | 325 kg |
| Mains voltage | 400 V (3-phase + neutral) | 400 V (3-phase + neutral) |
| Net weight | R407C | R407C |
| Price, EUR incl. VAT | 6050 | 6655 |
*In accordance with standard EN 255 at a collector temperature of 0° C / heating temperature of 35° C. The electrical power of the circulation pumps is not included.
**In accordance with standard EN 255 at a collector temperature of 0° C / heating temperature of 50° C. The electrical power of the circulation pumps is not included.
| Type, NIBE F1245 | 10 kW | 12 kW |
|---|---|---|
| Heating capacity (B 0 / W 35) * | 10,0 kW | 11,8 kW |
| Heating capacity (B 0 / W 50) ** | 8,5 kW | 11,2 kW |
| COP (B 0 / W 35) * | 5,03 | 4,8 |
| COP (B 0 / W 50) ** | 3,39 | 3,4 |
| Height | 1500 mm | 1500 mm |
| Required opening height for installation | 1950 mm | 1950 mm |
| Hot water tank volume | 180 litres | 180 litres |
| Width | 600 mm | 600 mm |
| Depth | 620 mm | 620 mm |
| Net weight | 330 kg | 335 kg |
| Mains voltage | 400 V (3-phase + neutral) | 400 V (3-phase + neutral) |
| Net weight | R407C | R407C |
| Price, EUR incl. VAT | 6775 | 7140 |
*In accordance with standard EN 255 at a collector temperature of 0° C / heating temperature of 35° C. The electrical power of the circulation pumps is not included.
**In accordance with standard EN 255 at a collector temperature of 0° C / heating temperature of 50° C. The electrical power of the circulation pumps is not included.
NIBE ground source heat pump FIGHTER 1226
NIBE FIGHTER 1226 is an improved heat pump for heating private homes and preparing domestic hot water.
NIBE FIGHTER 1226 has a convenient control panel and display that ensure easy operation. High efficiency is achieved thanks to an efficient compressor and a perfectly dimensioned refrigerant circuit. As a result, a high coefficient of performance can be achieved.
| Type, NIBE F1226 | 6 kW |
|---|---|
| Heating capacity (B0/W35 and B0/W50)* | 5.56 / 4.45 kW |
| Coefficient of performance* (COP) | 4,50 / 3,20 |
| Height | 1800 mm |
| Width | 600 mm |
| Depth | 620 mm |
| Net weight | 307kg |
| Mains voltage | 400 V (3 phases + N) |
| Refrigerant | R407C |
| Collector length | 250-350m |
| Borehole | 90-110m |
| Price, EUR incl. VAT | 5325 |
*In accordance with standard EN 255 at a collector temperature of 0° C / heating temperature of 35° C and at a collector temperature of
0° C / heating temperature of 50° C. The electrical power of the circulation pumps is not included.
| Type, NIBE F1226 | 8 kW | 11 kW |
|---|---|---|
| Heating capacity (B0/W35 and B0/W50)* | 7.63 / 6.32 kW | 11.01 / 10.32 kW |
| Coefficient of performance* (COP) | 4,71 / 3,36 | 4,55 / 3,25 |
| Height | 1800 mm | 1800 mm |
| Width | 600 mm | 600 mm |
| Depth | 620 mm | 620 mm |
| Net weight | 320 kg | 330 kg |
| Mains voltage | 400 V (3 phases + N) | 400 V (3 phases + N) |
| Refrigerant | R407C | R407C |
| Collector length | 325-2x250m | 2×230-2×300 |
| Borehole | 120-145m | 180-200m |
| Price, EUR incl. VAT | 5565 | 6050 |
*In accordance with standard EN 255 at a collector temperature of 0° C / heating temperature of 35° C and at a collector temperature of
0° C / heating temperature of 50° C. The electrical power of the circulation pumps is not included.
NIBE ground source heat pump FIGHTER 1255
The NIBE ground source heat pump FIGHTER 1255 is a smart, intelligent heat pump equipped with an inverter compressor and a speed-controlled circulation pump. It is suitable for residential and commercial buildings to ensure the most economical operation. The heat pump can automatically adapt itself to the building's energy demand by reducing or increasing the compressor speed. This provides optimal savings, so it always operates at the correct performance level throughout the year, without additional electricity losses. Three different corrosion protection options are available (stainless steel, enamel and copper). It can be connected to several products and accessories, such as a hot water heater, ventilation heat recovery, a pool, active cooling and heating systems with different temperatures.
| Type, NIBE F1255 | 4-16 kW |
|---|---|
| Capacity range from – to | 4 – 16 kW |
| Input power at 0/35°C *, 50 Hz (EN 255) | 1,81 kW |
| Output power at 0/35°C *, 50 Hz (EN 255) | 9,27 kW |
| COP 0/35°C * (EN 255) | 5,12 |
| Input power at 0/35°C *, 50 Hz (EN 14511) | 1,83 kW |
| Output power at 0/35°C *, 50 Hz (EN 14511) | 8,89 kW |
| COP 0/35°C (EN 14511) | 4,85 |
| SCOP ** (EN 14825) | 5,4 |
| Operating voltage | 400 V 3NAC 50 Hz |
| Hot water tank volume | 180 litres |
| Refrigerant charge R 407C | 2,2 kg |
| Maximum flow/return temperature at 0°C | 70/58 °C |
| Operating noise level (LwA) | 36-47 dBA |
| Net weight | 245 kg |
| Height | 1800 mm |
| Width | 600 mm |
| Depth | 620 mm |
| Price, EUR incl. VAT | 8710 |